290
WM-OM-E Rev I
Variable Names
Upper and lower case have no significance in VBS, either in variable names or in keywords (the
names reserved by the system), but it is a good idea to be consistent about the spelling of a
variable name to avoid confusion. At least 36 characters may be used in a variable name. These
can include any combination of alphabetic and numeric characters, and the underscore character.
No other punctuation character may be used in a variable name.
Do not use
any of the following characters in a variable name:
! @ & $ # ? , * . { } ( ) [ ] = + - ^ % / ~ < > : ;
Just use alphanumerics and underscore, for example: Example_Name
If you have to introduce constants, give them sensible names, just like variables. For example, do
not write:
_
If RMS < 23169 Then OutputY = Y
Its meaning may not be obvious to someone else.
It is better to write something like this:
FullScale = 32767
RootTwo = Sqr (2.0)
MaxRMS = FullScale / RootTwo
. . . . .
If RMS < MaxRMS Then . . . . .
But to keep your scripts fast, leave definitions like this outside your loops.
General usage
Note that white space has no effect, so you can introduce spaces for clarity, except of course within
variable names, function names and other keywords. Indenting control statements can be a great
help in understanding a program. For example:
For K = Kstart To Kstop
X = K * Sqr (3)
For N = NStart To Nstop
Y = N * N
If Y < FullScale Then
. . . . . .
. . . . . .
End If ' End of main calculation
Next ' End of N loop
Summary of Contents for DDA-3000A
Page 1: ...LECROY X STREAM OSCILLOSCOPES O P E R AT O R S M A N U A L SEPTEMBER 2006 ...
Page 18: ...16 WM OM E Rev I BLANK PAGE ...
Page 64: ...62 WM OM E Rev I icon in Channels dialog zooms one trace zooms all displayed traces ...
Page 80: ...78 WM OM E Rev I 4 Select a language 5 Click Next when the Wizard appears ...
Page 81: ...X Stream Operator s Manual WM OM E Rev I 79 6 Select Complete setup ...
Page 157: ...X Stream Operator s Manual WM OM E Rev I 155 ...
Page 170: ...168 WM OM E Rev I 5 Read the status information in line StatusDescription ...
Page 214: ...212 WM OM E Rev I Delay Parameter Find Range selected ...
Page 263: ...X Stream Operator s Manual WM OM E Rev I 261 ...
Page 284: ...282 WM OM E Rev I ...
Page 285: ...X Stream Operator s Manual WM OM E Rev I 283 Using a Surface Plot Excel Example 5 ...
Page 324: ...322 WM OM E Rev I ...