WR6K-OM-E Rev A
ISSUED: October 2003
375
Instantaneous Power Measurement – Event Triggered
Note:
The previous sections should be completed before you make these measurements.
To analyze the instantaneous power of the power device during transitions such as turn-on and
load change, trigger the acquisition on an "event" trigger:
The above is a 10 ms window of a power FETs drain-source voltage, drain current (deskewed),
and instantaneous power dissipation that occurs during the circuit’s transition from maximum to
minimum load. The zoom of the instantaneous power waveform (F1) is used to examine the
instantaneous power dissipation during one cycle in trace Pwr. In this case, the acquisition of the
10 ms record was triggered by the "event" trigger previously set up on Channel 4.