WR6K-OM-E Rev A
ISSUED: October 2003
99
,
,
.
7.
Touch inside the field below the
Qualify by:
buttons and enter a value using the numeric
keypad.
8.
To set up a Qualified First trigger, touch the
Qualify first segment only
checkbox if you
are in Sequence mode.
S
TATE
T
RIGGER
State trigger is another Qualified trigger; however, instead of using the edges of the qualifying
inputs, State trigger uses the logic state of the inputs to qualify the trigger. Therefore, the pattern
must become true and remain true (for a period of time or number of events that you specify) to
qualify the trigger.
See also How Qualified Triggers Work.
State Qualified and Wait: Trigger after timeout. The broken upward-pointing arrows indicate potential triggers,
while the bold arrows show where the actual triggers occur.
To Set Up a State Qualified Trigger
1.
In the menu bar, touch
Trigger
, then
Trigger Setup...
in the drop-down menu.
Summary of Contents for 6000 SERIES
Page 65: ...WR6K OM E Rev A ISSUED October 2003 63 Proper Orientation of Drive ...
Page 131: ...WR6K OM E Rev A ISSUED October 2003 129 Example ...
Page 141: ...WR6K OM E Rev A ISSUED October 2003 139 ...
Page 236: ...Operator s Manual 234 ISSUED October 2003 WR6K OM E Rev A Example 6 ...
Page 261: ...WR6K OM E Rev A ISSUED October 2003 259 ...
Page 286: ...Operator s Manual 284 ISSUED October 2003 WR6K OM E Rev A ...
Page 304: ...Operator s Manual 302 ISSUED October 2003 WR6K OM E Rev A ...
Page 307: ...WR6K OM E Rev A ISSUED October 2003 305 Convolve two signals ...
Page 348: ...Operator s Manual 346 ISSUED October 2003 WR6K OM E Rev A ...