Operator's Manual
98
ISSUED: October 2003
WR6K-OM-E Rev A
Qualified First Trigger
Qualified First trigger is intended to be used exclusively in Sequence Mode to speed up the
trigger rate. With Qualified First trigger, a single valid trigger is sufficient to acquire a full
sequence. Other than in Sequence Mode, Qualified First is identical to the Qualified triggers.
In data storage applications, the index pulse can be defined as the qualifier signal and the servo
gate signal as the trigger source.
To Set Up an Edge Qualified Trigger
1.
In the menu bar, touch
Trigger
, then
Trigger Setup...
in the drop-down menu.
2.
Touch the
Qualify
trigger button
3.
Touch inside the
Trigger On
data entry field and select a source on which to trigger.
4.
Select
Positive
or
Negative
slope.
5.
Touch inside the
After
data entry field and select the qualifying signal source from the
pop-up menu. If you select an input channel or external source, touch inside the
has
gone
data entry field and select a logic level:
Above
or
Below
. Then touch inside the
Level
field and set a voltage level using the pop-up numeric keypad. If you select
Pattern
from the pop-up menu, touch the
Pattern
tab and choose a logic gate. Then touch inside
the
State
field for each channel input you want to use in the pattern and select a logic
condition:
High
or
Low
. Select
Don't Care
for unused inputs. For the inputs to be used,
touch inside each
Level
field and enter a voltage threshold using the pop-up numeric
keypad. Then touch the
Trigger
tab again.
6.
If you want to set a holdoff in time or events, touch one of the
Qualify by:
buttons:
Summary of Contents for 6000 SERIES
Page 65: ...WR6K OM E Rev A ISSUED October 2003 63 Proper Orientation of Drive ...
Page 131: ...WR6K OM E Rev A ISSUED October 2003 129 Example ...
Page 141: ...WR6K OM E Rev A ISSUED October 2003 139 ...
Page 236: ...Operator s Manual 234 ISSUED October 2003 WR6K OM E Rev A Example 6 ...
Page 261: ...WR6K OM E Rev A ISSUED October 2003 259 ...
Page 286: ...Operator s Manual 284 ISSUED October 2003 WR6K OM E Rev A ...
Page 304: ...Operator s Manual 302 ISSUED October 2003 WR6K OM E Rev A ...
Page 307: ...WR6K OM E Rev A ISSUED October 2003 305 Convolve two signals ...
Page 348: ...Operator s Manual 346 ISSUED October 2003 WR6K OM E Rev A ...
Page 402: ...Operator s Manual 400 ISSUED October 2003 WR6K OM E Rev A ...