3. PANEL DESCRIPTION
37
3. PANEL DESCRIPTION
3.1
Front Panel
Figure 3-1 Front panel
Table 3-1 Front panel description
No.
Name
Description
1
Power switch Press this switch to turn the instrument on. Hold this switch down to turn the
instrument off.
See section 4.3, “Turning the Instrument On and Off.”
2
EXT
Switches the SDI signal sync signal. When the internal sync signal is being used,
this key's LED turns off. When the external sync signal is being used, this key's
LED lights.
See section 4.5.4, “External Sync Signal Input (LV 5770SER08 and LV
5770SER09A).”
3
SYS
Configure settings for the instrument and the installed optional units.
See chapter 7, “SYSTEM SETTINGS.”
4
SHORTCUT
Loads panel settings, adjusts the volume, saves a screen capture to the USB
memory device, or adjusts the intensity.
See sections 4.7.5, “Operating the Shortcut Key” and 7.4, “Setting the Shortcut
Key.”
5
CAP
Captures the screen or frame data.
See chapter 8, “CAPTURE FEATURE.”
6
MEM
Registers or deletes a single preset, or copies all presets.
See chapter 9, “PRESET FEATURE.”
7
RCLL
Loads a preset.
See chapter 9, “PRESET FEATURE.”
8
SDI
Measures the SDI signal being applied to the LV 5770SER08 or LV 5770SER09A.
9
CMPST
Measures the composite signal or HD tri-level sync signal being applied to the LV
5770SER03A.
10
A/B
Select the input channel of the SDI signal.
See section 5.4, “Selecting the Input Channel.”
11
SIM
Switches the SDI signal input mode. In single input mode, this key's LED turns off.
In simul mode, this key's LED lights.
See section 5.4, “Selecting the Input Channel.”
12
WFM
Shows the video signal waveform display. This requires the LV 5770SER03A, LV
5770SER08, or LV 5770SER09A.
See section 5.5, “Selecting the Display Mode”
13
VEC
Shows the vector display. This requires the LV 5770SER03A, LV 5770SER08, or
LV 5770SER09A.