10. REMOTE CONTROL
100
●
Configuring the LV 7770
To set the remote control connector, use the system settings. For details, see section 7.2.3,
“Remote Control Settings.”
SYS
→ F•2
SYSTEM SETUP → F•3
NEXT TAB →
F•3
NEXT TAB →
Figure 10-2 REMOTE SETUP tab
●
Remote Control
The input connectors respond to active-low signals. Do not apply negative voltages or
voltages that 5 V. After you make a setting, a period of time of 350 ms or more in
which the electrical potential is stable is required, so wait at least 1 second before you make
the subsequent setting.
Figure 10-3 Remote control timing 1