8. CAPTURE FEATURE
89
●
Capturing frame data automatically (error capture)
4. Press
F•1
TRIGGER to select ERROR.
5. Press
F•
2 REFRESH.
The LV 7770 switches to error standby mode and displays the message “ERR CAP” at
the top of the screen. The standby mode is cleared when you change the input channel
or other settings.
Figure 8-8 Error standby
6. When the message below appears, press any key except for the power key.
If an error occurs during error standby, the LV 7770 captures the frame data at that point
and stops the frame capture. (In simul mode, if an error occurs on channel A or channel
B, the LV 7770 captures the frame data of the channel in which the error occurred and
stops the frame capture.)
The applicable errors are those listed under “Applicable Errors” below whose detection
setting has been set to ON through
F•6
ERROR SETUP on the status menu.
Table 8-1 Applicable errors for error capturing
Applicable Errors
Inapplicable Errors
SDI Error
TRS, Line Number, CRC, EDH, Illegal Code
Cable
Ancillary Data Error
Parity, Checksum
-
Embedded Audio Error
BCH, DBN, Parity, Inhibit Line
Sample Count
Video Error
Gamut, Composite Gamut, Level
Freeze, Black
Figure 8-9 Error capture end