2. SPECIFICATIONS
18
2.3.18
Other Display Settings
Input Information Display
Input channel, ID, OFF
Input Channel Display
Displays the selected channel (A, B, C, or D)
ID Display
Up to 10 characters for each input channel
Time Code
LTC, VITC, OFF
Compliant Standard
SMPTE 12M-2 (decoded from ANC-TC)
(When the link format is set to dual, only link A is
decoded.)
Format Display
The format can be displayed when an SDI signal is
detected.
Tally Indication
Displays tally indications for each input channel (when
an OP70 is installed)
2.3.19 Front
Panel
Key LEDs
All the keys are dimly back-lit, and the selected key is
lit more brightly
Power Switch
Stores whether the instrument is on or off
Last Memory
Backs up the panel settings to memory
2.3.20 General
Specifications
Environmental Conditions
Operating Temperature Range
0 to 40 °C
Operating Humidity Range
85 %RH or less (no condensation)
Optimal Temperature
10 to 30 °C
Power Supply
Voltage
10 to 18 VDC
Power Consumption
46 W max.
Dimensions
215 (W) × 176 (H) × 111 (D) mm (excluding feet)
Weight 2.2
kg
Accessories AC
adapter (SPU63-105)......................................... 1
Instruction manual.................................................... 1
15-pin D-sub connector (when an OP70 is installed) 1
15-pin D-sub connector bar (when an OP70 is
installed)................................................................... 1
2.3.21 AC
ADAPTER
(SPU63-105)
Input
100 to 240 VAC, 50/60 Hz, 1.6 A
Output
12 VDC, 4.75 A max.
Dimensions 52(W)×34.5(H)×118(D) mm (without power cord)
Weight