14. STATUS DISPLAY
166
14.4.3
Scrolling through the Data Dump
To scroll through the data dump, follow the procedure below.
Procedure
STATUS
→
F•2 SDI ANALYSIS
→
F•1 DATA DUMP
→
F•D 1 SAMPLE SELECT
14.4.4
Selecting the Display Mode
To select the data dump display mode, follow the procedure below.
Procedure
STATUS
→
F•2 SDI ANALYSIS
→
F•1 DATA DUMP
→
F•1 MODE: RUN / HOLD
Settings
RUN:
The input signal data is automatically updated and displayed.
HOLD:
The input signal data is retained and displayed.
14.4.5
Selecting the Display Format
To select the data dump display format, follow the procedure below.
The types of display formats that you can select vary depending on the link format. (Dual
link signals are supported as an option.)
Procedure
STATUS
→
F•2 SDI ANALYSIS
→
F•1 DATA DUMP
→
F•2 DISPLAY:
SERIAL / COMPO (Single link)
LINK A / LINK B / LINK AB (Dual link)
Settings (when the link format is set to single)
SERIAL:
The data is converted from parallel to serial data and displayed.
COMPO:
The data is converted from parallel to serial data, split into Y, Cb, and Cr, and
then displayed.
Settings (when the link format is set to dual)
LINK A:
The parallel converted data sequences of link A are displayed.
LINK B:
The parallel converted data sequences of link B are displayed.
LINK A/B:
Links A and B are combined, and their parallel data sequences are displayed.