116
c
HAPTER
4:
Computer Interface Operation
MeasureReady™ M91 FastHall™ Measurement Controller
"PositiveExcitationVoltageOverload": false,
"PositiveExcitationCurrentOverload": false,
"NegativeExcitationHallVoltageAverageInVolts": 0.0082348906,
"NegativeExcitationHallVoltageStandardErrorInVolts":
1.4553178896724013E-06,
"NegativeExcitationCurrentAverageInAmp": 0.0099953324,
"NegativeExcitationInCompliance": false,
"NegativeExcitationVoltageOverload": false,
"NegativeExcitationCurrentOverload": false
},
"NegativeFieldResultsSummary": {
"PositiveExcitationHallVoltageAverageInVolts": -0.0082633413999999988,
"PositiveExcitationHallVoltageStandardErrorInVolts":
4.4750247105464231E-06,
"PositiveExcitationCurrentAverageInAmps": 0.0099949398,
"PositiveExcitationInCompliance": false,
"PositiveExcitationVoltageOverload": false,
"PositiveExcitationCurrentOverload": false,
"NegativeExcitationHallVoltageAverageInVolts": 0.0082451744,
"NegativeExcitationHallVoltageStandardErrorInVolts":
2.2773556727048522E-06,
"NegativeExcitationCurrentAverageInAmp": 0.0099951196,
"NegativeExcitationInCompliance": false,
"NegativeExcitationVoltageOverload": false,
"NegativeExcitationCurrentOverload": false
},
"CarrierType": 1,
"PTypeCount": 5,
"NTypeCount": 0,
"InCompliance": false,
"VoltageOverload": false,
"CurrentOverload": false
},
"ActualBlankingTimeInSeconds": 0.1,
"ActualSamplingTimeInSeconds": 0.0.0166666666666667,
"InCompliance": false,
"VoltageOverload": false,
"CurrentOverload": false,
},
"DcHallSamples": [
{
"HallVoltageInVolts": -1.2479799698861455E-07,
"GeometryCHallVoltageInVolts": -3.0194351555753589E-07,
"GeometryDHallVoltageInVolts": 5.2347521580306795E-08,
"CurrentAverageInAmps": 0.0099953415000000011,
"GeometryCCurrentAverageInAmps": 0.00999557775,
"GeometryDCurrentAverageInAmps": 0.00999510525,
"CarrierType": 1,
"PositiveFieldGeometryCData": {
"ContactConfiguration": "V3142",
"PositiveExcitation": {
"VoltageInVolts": 0.008414321,
"CurrentInAmps": 0.00999526,
"ExcitationSetpoint": 0.01,
"InCompliance": false,
"VoltageOverload": false,
"CurrentOverload": false
},
"NegativeExcitation": {
"VoltageInVolts": -0.008328633,
"CurrentInAmps": -0.00999577,
"ExcitationSetpoint": -0.01,
"InCompliance": false,
"VoltageOverload": false,
"CurrentOverload": false
}
},
"PositiveFieldGeometryDData": {
Summary of Contents for Measure Ready M91 FastHall
Page 6: ...MeasureReady M91 FastHall Measurement Controller ...
Page 10: ...MeasureReady M91 FastHall Measurement Controller ...
Page 64: ...54 cHAPTER 3 Operation MeasureReady M91 FastHall Measurement Controller ...
Page 156: ...146 cHAPTER 4 Computer Interface Operation MeasureReady M91 FastHall Measurement Controller ...
Page 160: ...150 cHAPTER 5 Options and Accessories MeasureReady M91 FastHall Measurement Controller ...
Page 174: ...164 cHAPTER 6 Service MeasureReady M91 FastHall Measurement Controller ...