4.1 INTRODUCTION
This chapter contains general flight-line maintenance and troubleshooting procedures for installations
interfaced to WX-1000/SKY497 display or an alternate display. Removal of components is on condition
of failure. Troubleshooting is intended to aid in isolating failures to a defective assembly.
CAUTION
Each time the TRC, directional antenna, or directional antenna cables
(including connectors) are installed, removed or replaced, the TRC must
be calibrated to the directional antenna (refer to paragraph 4.4.3).
4.2 CONTINUED AIRWORTHINESS
No scheduled maintenance is required to ensure continued airworthiness. Removal of components is on
condition of failure.
4.3 PERIODIC MAINTENANCE
At regular inspection intervals, do the periodic maintenance procedures of paragraph 4.3.1 thru 4.3.3.
4.3.1 WX-1000/SKY497 Display
1.
Check that indicator cable is properly mated and secured.
2.
Check to ensure unit is properly placed and secured to the instrument panel.
CAUTION
Do not use cleaning solvents on the viewing face.
3.
Check face-plate for cleanliness. Wipe the viewing face with a damp lint-free, static-free cloth. If
necessary, clean with a soft cloth moistened with a mild solution of soap and water. Take care to
prevent cleaning solution from running down inside the case.
4.3.2 TRC
1.
Check that connectors are properly mated and secure.
2.
Check to ensure that the hold-down knobs on the mounting tray are secured to the TRC.