SKY899
Installation Manual
009-11900-001
Appendix C - Page C-3
Revision F
July 18, 2013
Figure C-2: Start-up Screen
After approximately thirty seconds the display will show the STANDBY screen (see figure C-3).
NOTE
If the TRC has not been calibrated to the directional antenna the display
may show a “SKY899 FAILED” message. Calibration will be done
during system setup verification and operation.
Figure C-3: Standby Screen
4.
Perform System Setup in paragraph 3.3.1. (If System Setup has already been done, proceed to next
step.)
5.
Turn SKY899 OFF and then enter the Service Menu (see paragraph 4.4) by holding the left two
buttons (soft-keys 1 and 2) depressed as the system is turned ON.
6.
From the Service Menu, calibrate the TRC to the directional antenna (see paragraph 3.3.2 and 4.4.3).
7.
Cycle power to the SKY899 and verify the standby screen appears after approximately 30 seconds.
Press OPR soft-key (4) and verify the MSG label does not appear on the display after 10 seconds.
NOTE
If MSG label is present press MSG soft-key (1) for degraded operation
message and refer to Chapter 4 troubleshooting to isolate the problem
before proceeding.