CAUTION
The Flightline Tester is not weatherproof when the lid is open. Do not
setup or operate the Flightline Tester in conditions of rain, sleet, etc.
10.
Setup and verify operation of the TT391 Flightline Tester:
a. Open the chassis lid and remove the lid from the chassis by sliding the lid off of the hinge pins
(sliding it to the right). The lid "stay" must be removed from the lid before mounting. The stay
will pop off of the lid. (The stay is the hinged part that props the lid open on the chassis).
NOTE
The Patch Antenna may be used without a tripod. The Patch Antenna can
be held, or secured, and pointed towards the SKY899 aircraft under test
WITH THE MOUNTING STUD POINT TOWARD THE GROUND
.
This
orientation is critical
b. Mount the chassis lid, with the Patch Antenna facing the aircraft, onto a tripod (not included).
The tripod must be capable of holding the antenna (approximately 2.5 lb.) and must provide a
standard base mounting stud threaded 1/4"-20. A typical tripod mount is shown in
.
Figure F-4.
c. If the internal batteries are being utilized, proceed to sub-step f. If the Flightline Tester AC
Converter Power Supply is to be utilized, proceed to sub-step d.
d. Connect the AC Converter Power Supply cable connector to the chassis external connector.
e. Connect the AC Converter Power Supply input power cable connector to one of the following AC
sources:
•
115 V ac, 60 Hz
•
115 V ac, 400 Hz
f. Set the Flightline Tester POWER switch to the ON position.
g. Verify that the LOW indicator is not steady on (it may flash). If the LOW indicator remains on
(i.e., lit), perform one of the following three options:
•
Use the AC Converter Power Supply to power the unit.
•
Recharge the internal batteries.
•
Replace the internal batteries.
h. Set the SELF-TEST switch to the 1030 position and verify that the 1030 indicator blinks on for
1/2 second every 5 seconds.
i. Set the SELF-TEST switch to the 1090 position and verify that the 1090 indicator blinks on for
1/2 second every 5 seconds.