Step 1: Calibrate the Carriage Stop
KVAL Operation Manual
3-12
Procedure
In this calibration, process a known good square on the hinge and lock edge of the door. Measure
the
location
of the square.
1.
Before calibrating the tools, update or check the
Tool Configuration
of the tool being
calibrated.
See “About the Tool Config Tabs” on page 2-26.
2.
Set the
Movable stop to 0.
3.
Create a Edge Rectangle
Door Job
on the
Hinge
side and the
Lock
side.
4.
Add
Door Job
to the
Queue
.
5.
Once the cut has been made, check the locations of both
Hinge
and
Lock
cuts.
6.
Perform the Left Hand Rule at the edge of the door to determine axis direction.
• If the location is out of specification on the
Lock
side and
Hinge
side is good,
adjust the
Lock Stop.
(Movable)
• If the location is out of specification on the
Hinge
side and
Lock
side is good,
adjust the
Hinge Stop.
(Fixed)
• If both the Lock and Hinge cuts are out of specification, go to the
Carriage Axes
Calibration.
See “Step 2: Calibrate the Carriage Axis” on page 3-13.
7.
If not in specification, adjust the location. Repeat until specification is reached. For
polarity of value to enter,
Summary of Contents for MLX
Page 59: ...About the Tool Config Tabs 2 29 KVAL MLX Operation Service Manual ...
Page 64: ...Description of the Light Tower KVAL MLX Operation Service Manual 2 34 ...
Page 90: ...System IT Administration KVAL MLX Operation Service Manual 4 4 ...
Page 117: ...Collet Torque Values 5 27 KVAL MLX Operation Service Manual ...
Page 118: ...Collet Torque Values KVAL MLX Operation Service Manual 5 28 ...
Page 141: ......
Page 142: ......
Page 143: ......