Step 2: Calibrate the Carriage Axis
KVAL Operation Manual
3-14
7.
FIGURE 3-2.
Carriage Axis
Face Carriage Axis Calibration Reference Cut (Option)
In this calibration, cut a known square on the face of the door. Measure the
location
of the square.
1.
Before calibrating the tools, update or check the
Tool Configuration
of the tool being
calibrated.
See “About the Tool Config Tabs” on page 2-26.
2.
Create a
Face Rectangle Door Job
of your choice.
3.
Add
Door Job
to the
Queue
.
4.
Once the cut has been made, check the location of the cut.
5.
Perform the
Left Hand Rule
from the
Face Router
reference to determine axis direction.
See the figure on the next page.
• If the location is out of specification in the
length
of the door, the
X-Axis
needs to
be adjusted.
• If the location is out of specification in the
width
of the door, the
Y-Axis
needs to
be adjusted.
• If the plunge cut is out of specification, check the
Configuration Menu
then verify
the
Z-Axis.
6.
If not in specification, adjust the location. Repeat until specification is reached.
+
X
+
Y
+
Z
-
X
-
Z
-
Y
Summary of Contents for MLX
Page 59: ...About the Tool Config Tabs 2 29 KVAL MLX Operation Service Manual ...
Page 64: ...Description of the Light Tower KVAL MLX Operation Service Manual 2 34 ...
Page 90: ...System IT Administration KVAL MLX Operation Service Manual 4 4 ...
Page 117: ...Collet Torque Values 5 27 KVAL MLX Operation Service Manual ...
Page 118: ...Collet Torque Values KVAL MLX Operation Service Manual 5 28 ...
Page 141: ......
Page 142: ......
Page 143: ......