46
5.3.2 REFITTING THE SENSOR
Before refitting the sensor, grease the sensor and the mounting hole.
When refitting the sensor, it should slide into its housing without being
forced. If the sensor does not go in easily, check the mounting hole;
repair or replace the mounting if necessary.
Rear sensor
- Take the new sensor and feed the wire through the sensor housing.
- Fit the sensor with the wire on the right, viewed from the thread side.
If the sensor is fitted the wrong way round, the weight indicated will be
incorrect.
- Use a mallet to fit the sensor, taking care to bring the wire through with it.
- Carry out the reverse of the dismantling procedure.
Front sensor
- Take the new sensor and feed the wire through the tube provided on the towbar body.
- Fit the sensor with the wire on the left, viewed from the thread side.
If the sensor is fitted the wrong way round, the weight indicated will be
incorrect.
- Secure the sensor in its place.
- Carry out the reverse of the removal procedure.
When tightening the nut (6), leave sufficient play (about 5 mm) to allow the collar to turn
Connection
- Fit the wire onto the chassis and the body and thread it through the sleeve up to the unit.
- Connect the wires on the connector in the right order (see the section on “Connecting to the printed
circuit board”.
- Tighten the cable gland onto the weighing unit, ensuring that the unit is properly sealed: the seal
should be present and the wire properly tightened.
Summary of Contents for IND 360P
Page 23: ...23 NOTES ...