42
This operation is to be carried out in a clean, damp-free building. If
these conditions are not observed, the weighing unit or sensors can
fail due to moisture and dust. Take all necessary precautions.
REASONS FOR REFUSAL OF WARRANTY
Return of the sensor with the wire cut.
Return of the sensor or weighing unit in poor condition.
Return of a printed circuit board which is damaged or on which electronic
components have been disconnected.
Return of a sensor or weighing unit damages due to poor packaging.
Removal of the front panel on IND 900.
5. FITTING AND REMOVING THE SENSORS AND THE UNIT
5.2 MACHINES WITH CHASSIS
5.2.1 REMOVING AND REFITTING THE Ø 54 DEFLECTION SENSOR
Necessary tools:
24 mm spanner, crosshead screwdriver, small electrician’s screwdriver, mallet, slide hammer, axle
stand and bottle jack.
- Remove the front of the unit.
- Disconnect the faulty sensor, remove the connector and
unscrew the gland.
- Take the wire out of the unit and the protective sleeve.
- Remove any cable ties and free the sensor cable from the
rest of the machine.
- Check that the wire is not damaged as this could be the
cause of the failure.
- Remove the screws (1).
- Using a jack, lift the body near to the sensor
(6 to 7 cm) and secure with an axle stand.
- Remove the sensor carefully without dropping it (2).
5.1 GENERAL