BAT. AUX.+: auxiliary battery red wire; indicator lamp brown wire
BAT.AUX.-: auxiliary battery blue wire; indicator lamp blue wire
Alim+: brown
Alim -: blue
Aff+: brown
Tx:
yellow/green
Secondary display
Aff-: blue wire and brown wire
}
TESTING OF SENSORS BU05 (
∅
40) AND FL05 (SHAFT)
Power impedance (between power+ and power-): from 350
Ω
to 410
Ω
Measurement impedance (between meas and measurement-): from 350
Ω
to 355
Ω
Sensor insulation (between shielding and each wire from the sensor): over 20 Giga
Ω
TESTING OF DEFLECTION SENSORS (
∅
∅
∅
∅
∅
54)
Power impedance (between power+ and power-): 375 ± 10
Ω
Measurement impedance (between meas and measurement-): 350
± 5 Ω