41
Power supply: 12 V, consumption 380 mA (in addition to the 400 mA indicator consumption - beware
when using with an internal battery).
LED display unit:
- height: 80 mm, width: 230 mm, depth: 65 mm
- operating temperature: -30°C to +50°C
Digit size: 55 mm high, 30 mm wide
Plastic casing:
- shockproof
- sealed to IP 65
Direct connection to IND 360 indicator unit (see 3.4)
Tx = Yellow/green NF = black A+ = brown A - = blue
Direct connection to IND 900 indicator unit (see 2.4)
Tx = Yellow/green
Aff+ = brown Aff- = blue and black
CE approved.
If the secondary display fails to light up:
- Go to the IND360 main menu.
- Select “5. Options”, then “Print”, then “INACTIVE” (cf. User Manual).
4.4 IND700 REMOTE DISPLAY (Secondary display)