3.2.2 SIMPLE MAINTENANCE
PROGRAMMABLE VERSION (IND 360P): first go to the GENERAL MENU
To access to the MAINTENANCE MENU, press and the key to the left of the key at the
same time.
Press to display the help page, press a second time to go back to the GENERAL MENU.
1- SENSOR TEST. Press key 1 to check the state of the
sensors (see description in 3.2.2.1).
2- CALIBRATION. Press key 2 to calibrate the weighing
unit (for example, if you have changed a sensor, see
3.2.2.2).
3- CONFIRMATION OF THE TARE. Press key 3 to re-tare
the weighing unit to its original setting (see 3.2.2.3).
4- DELETING OF THE PROGRAMS
Press key 4 to delete all programs (see 3.2.2.4).
Press the EXIT key to return to the GENERAL MENU.
3.2.2.1 SENSOR TEST
Press to display the help page, press a second time to return to sensor test.
Press key 3 if the machine has 3 sensors.
Press key 4 if the machine has 4 sensors.
3 sensors: all straw blowers and mixers, EUROMIX 8 N
and F and 10, 12 N.
4 sensors: EUROMIX 10 and 12 F.
N.B. If a 4-sensor test is selected for a machine which is
equipped with 3 sensors, the display will read “sensor 4 in
failure”. If the 3 sensors are not correctly connected to the
board, the display will read “sensor 1 in failure”.
As an example, we shall choose a test for a machine
equipped with 3 sensors.
All sensors are good.
Press EXIT to return to the MAINTENANCE MENU
IN THE EVENT OF A FAULT, RUN THE SELF-TEST (see § D1.6 “DISPLAYING THE
VOLTAGE OF THE SENSORS”)
?
MENU
MAINTENANCE
1 - Sensor test
2 - Calibration
3 - Confirmation of the tare
4 - Deleting of the programs
1 2 3 4 5 Exit
SENSORS TEST
Test of three sensors
Sensor No 1 good
Sensor No 2 good
Sensor No 3 good
EXIT
SENSORS TEST
Number of sensors ?
3 4 EXIT
OK
OK
?