30
3.2.2.2 CALIBRATION USING A KNOWN WEIGHT
TO MAKE USE OF THIS FUNCTION, YOU NEED A KNOWN WEIGHT
OF AT LEAST ONE TONNE
(see 3.2.2.1, Calibration without a known weight, from factory data)
To avoid any mistakes, before you begin machine calibration, check the sensors with the
help of the function in 3.2.3.1 “Testing the sensors”.
Enter the code 5141 with the modification keys X... , .X.. , ..X. and ...X at the bottom of the screen.
Press to validate the code (a mistake will involve returning to the Maintenance menu).
Machine empty
Enter 0000, then press . Do not touch the machine
while “Wait a minute, please” is displayed.
Machine loaded with the known weight.
Enter the second value, for example the value of the factory
known weight: 2135.
Do not touch the machine while “Wait a minute, please” is
displayed.
The screen then displays the calibration caracteristics. The
factory calibration caracteristics are printed inside the unit.
These are usable for a calibration without a known weight
(see 3.2.3.1 Acquisition of the standard values).
Press EXIT to return to the MAINTENANCE MENU.
OK
CALIBRATION
Empty machine: 0 0 0 0
Wait please
Loaded machine: 2.1.3.5
Wait please
EXIT
OK