Servicing the Timeclock
Series 4000 Badge Timeclock User’s Guide
4-35
9. Use a utility knife to remove the two round spacers from the back of the
timeclock where the transformer had been positioned.
10. Install the transformer back in the timeclock as follows:
a.
Position the transformer behind the wire clip in the timeclock.
b. Route the transformer cable to its connection point on the main board and
plug the connector in.
c.
Plug the transformer back into the AC outlet. If you are plugging the
timeclock into an external AC outlet, route the power cord out of the
timeclock and re-assemble the strain relief clip to secure the cord.
11. Close and lock the timeclock cover using the security wrench.
Number
Description
1
Badge reader spacers molded into the base.