Terminals for electrical installation (one current output / one switch output - relay)
Figure 4-12: Terminals for electrical installation (one current output / one switch output - relay)
1
Current output 1: Terminals
2
Switch power supply: Terminals
3
Switch output - relay: Terminals
4
Location of the external grounding terminal (on the wall support)
5
Grounding terminal in the housing (if the electrical cable is shielded)
CAUTION!
•
Use the applicable electrical cables with the cable glands.
•
Current outputs: Make sure that the current is not more than 4 A or that there is 4 A-rated
fuse in the electrical circuit that energizes the device.
•
Switch output - relay: Make sure that the current is not more than 5 A or that there is 5 A-
rated fuse in the electrical circuit that energizes the device.
•
Make sure that the polarity of the power supply is correct. If the polarity is incorrect, you will
not cause damage to the device but the device will not operate.