![KROHNE OPTIFLEX 8200 C Handbook Download Page 189](http://html1.mh-extra.com/html/krohne/optiflex-8200-c/optiflex-8200-c_handbook_2004181189.webp)
DESCRIPTION OF HART INTERFACE
9
189
OPTIFLEX 8200 C/F/S
www.krohne.com
06/2018 - 4006448901 - MA OPTIFLEX 8200 R01 en
Detailed Setup
Advanced Setups
Language / Length Unit (On Local Display) /
Conversion Unit (On Local Display) / Display Mode
Conversion Table (Add One Point / Modify One
Point / Delete Last Point / Delete Table)
Counter Weight Height / Probe End Pulse Type /
Electronic Offset / Mechanical Offset / Calspeed
Elec. / Calspeed Meca. / Minimum Window /
Calspeed Installation / Flange Threshold / Flange
Detection Delay / Noise Cancelling / Epsilon R
Product / Epsilon R Product mini. / Epsilon R
Product maxi. / Product Family / Level Lost Alarm /
Overfill Alarm / Temperature Out Of Range Alarm /
Empty Alarm / Interface Lost Alarm / Leak Detection
Alarm / Probe Analysis / Snapshot Recording /
Output Calibration I1 / Output Calibration I2 / Reset
Error records / Event Log Filter / Erase Probe
Analysis / Erase Snapshot Record / Auto Offset
Calculation
Full Area / Empty Area / Minimum Layer / Pulse
Search Mode / Attenuation Factor / Bottom Blocking
Distance Direct / Bottom Blocking Distance TBF /
Option 1 / Option 2 / Option 3 / Option 4 / Option 5 /
Option 6 / Option 7 / Option 8 / Option 9 / Option 10 /
WHG Mode / Reference Point 1 / Correction Point 1 /
Reference Point 2 / Correction Point 2 / Reference
Point 3 / Correction Point 3 / Reference Point 4 /
Correction Point 4 / Parasite Threshold / Min. Layer
for Prod. Recognition / Probe Head Attenuation /
Impedance Ratio / Number of Point for Leak
Detection / Number of Singular Value for Leak
Detection / Snapshot Size / Save as Factory Config. /
ASIC Pulse Selection Mode / ASIC Pulse Width /
ASIC Pulse Amplitude / ASIC Pulse Sign / ASIC Gain
Amplifier Linear / ASIC Gain Amplifier Log / ASIC
LoW Pass Filter / ADC Sampling Rate / Log
Compensation
Info.
Identification:
Serial Number
Rd
/ Converter Firmware Version
Rd
/
Sensor Firmware Version
Rd
/ HMI Firmware
Version
Rd
Current Output:
Output Function
Rd
/ Output Range
Rd
/ PV LRV
Rd
/ PV
URV
Rd
/ Output Error Delay
Rd
Basic Parameters
Tank Height / Block Distance / Time Constant /
Length Unit (HART) / Conversion Unit (HART) / Tag
Current Output
Output Function / Output Range / PV LRV / PV URV /
Output Error Delay / Loop current mode