Kramer Electronics Ltd.
VS-622DT
– Protocol 3000
85
GPIO-VOLT?
Command Name
Permission
Transparency
Set:
-
-
-
Get:
GPIO-VOLT?
End User
Public
Description
Syntax
Set:
Get:
Get voltage levels of HW GPIO
#GPIO-VOLT?
SP
HwGpioNumber
CR
Response
~nn@
GPIO-VOLT
SP
HwGpioNumber,Voltage
CR LF
Parameters
HwGpioNum
–
1
(GPIO 1),
2
(GPIO 2)
Voltage
– voltage
0
to
30000
millivolts
Notes
This command is not available in digital out mode
K-Config Example
Get GPIO 1 voltage:
“#GPIO
-
VOLT? 1”,0x0D
IR-SND
Command Name
Permission
Transparency
Set:
IR-SND
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Send IR command to port
#IR-
SND
SP
PortNum,Cmdid,CmdName,Repeat,
TotalPackages,PackageNum,<pronto
command…
>
CR
Get:
-
-
Response
~nn@
IR-SND
SP
PortNum,Cmdid,CmdName,Status
CR LF
Parameters
Port_Num
–
1
(IR port 1),
2
(IR port 2),
3
(IR port 3),
4
(IR port 4),
*
(broadcasts to all ports)
Cmd_id
– serial number of command for flow control and response commands from device
CmdName
– command name (length limit 15 chars)
Repeat
– number of times the IR command is transmitted (limited to 50; repeats > 50 are truncated
to 50), default = 1
Total_packages
– number of messages the original command was divided into,
1
(Default)
Package_num
– chunk serial number (only valid when
Total_packages
>
1
)
Pronto command
– Pronto format command (in HEX format, no leading zeros, no ‘0x’ prefix)
Status
–
0
(Sent),
1
(Stop),
2
(Done),
3
(Busy),
4
(Wrong Parameter),
5
(Nothing to Stop),
6
(Start),
7
(Timeout),
8
(Error)
K-Config Example
Send IR command via IR Port 2 (the command number is set to 3 it should be repeated 4 times the
total packages is 5 and package 2 is sent:
“#IR
-SEND 2,3,
command name
,4,5,2,
pronto format
”,0x0D