Kramer Electronics Ltd.
VS-622DT
– Managing IO Gateway Settings
45
5. Click
OK
.
Figure 46: IO Gateway Page
– GPIO Digital OUT
6.
Enable
/
Disable
Pull-up resistor.
7. Set Current Status to
High
/
Low
.
8. Click
Save Changes
.
The Digital OUT GPIO port is configured.
Configuring the Analog Input Trigger Type
In the Analog In trigger type, the port is triggered by an analog external device, such as, a
volume control device that changes gradually. The trigger is activated once when the detected
voltage is within 0 to 30V DC voltage range.
•
You can select the number of steps the analog input signal will be divided into, starting
with step 1 to a maximum of 100.
The voltage of each step is dependent on the number of steps selected:
The individual step voltage equals 30V divided by the number of steps.
To configure the analog input trigger type:
1. In the Navigation pane, click
IO Gateway
. The IO Gateway page appears (see
).
2. Click
GPIO
).
3. Select
GPIO 1
or
GPIO 2
.