Kramer Electronics Ltd.
VS-622DT
– Protocol 3000
63
NAME
Functions
Permission
Transparency
Set:
NAME
Administrator
Public
Get:
NAME?
End User
Public
Description
Syntax
Set:
Set machine (DNS) name
#NAME
SP
machine_name
CR
Get:
Get machine (DNS) name
#NAME?
CR
Response
Set:
~nn
@NAME
SP
machine_name
CR LF
Get:
~nn
@NAME
SP
machine_name
CR LF
Parameters
machine_name
– String of up to 14 alpha-numeric characters (can include hyphens but not at the
beginning or end)
Notes
The machine name is not the same as the model name. The machine name is used to identify a
specific machine or a network in use (with DNS feature on).
K-Config Example
Set the DN
S name of the device to “room-442”:
“#NAME room
-
442”,0x0D
NAME-RST
Functions
Permission
Transparency
Set:
NAME-RST
Administrator
Public
Get:
-
-
-
Description
Syntax
Set:
Reset machine (DNS) name to
factory default
#NAME-RST
CR
Get:
-
-
Response
~nn
@NAME-RST
SP
OK
CR LF
Notes
Factory default of machine (DNS) name is “KRAMER_” + 4 last digits of device serial number
K-Config Example
Reset the machine name (S/N last digits are 0102):
“#NAME
-
RST KRAMER_0102”,0x0D