CAUTION: Installation of the gas line
must only be done by a qualified person in
accordance with local building codes, if any.
If not, follow ANSI 223.1.
(In the Commonwealth of Massachusetts installation
must be done by a licensed plumber of gas fitter).
This fireplace is manufactured for use with Natural Gas. An LP conversion kit, is included with this fireplace. Follow instructions
included with the conversion kit if converting to LP gas.
Model DSL-36;
#OCK-S53A
Model DSL-36-RF; #OCK-H53L-RF
NOTE: This fireplace is equipped with a 3/8”(10
mm) x 18” (457 mm) long flexible gas connector and
manual shut-off valve. The gas line should be run to
the point of connection where the shut-off valve and
flexible gas line will connect.
NOTE: For high altitude installations, consult
the local gas distributor or the authority having
jurisdiction for proper rating methods
.
DSL-36
DSL-36-RF
NATURAL GAS
LP GAS
NATURAL GAS
LP GAS
MINIMUM INLET GAS PRESSURE
5.0 inches W.C.
(7.0 W.C. recommended)
11.0 inches W.C.
(recommended)
5.0 inches W.C.
(7.0 W.C. recommended)
11.0 inches W.C.
(recommended)
MAXIMUM INLET GAS PRESSURE
10.5 inches W.C.
13.0 inches W.C.
10.5 inches W.C.
13.0 inches W.C.
MANIFOLD PRESSURE (HI)
3.8 inches W.C
10.0 inches W.C.
3.5 inches W.C
10.0 inches W.C.
MANIFOLD PRESSURE (LO)
1.1 inches W.C.
6.3 inches W.C
1.7 inches W.C.
6.3 inches W.C
ORIFICE SIZE
#42
#53
3/32 (.093)
#53
INPUT BTU/hr.
26,000
24,000
26,000
24,000
MINIMUM INPUT BTU/hr.
13,000
12,000
13,000
12,000
EFFICIENCY
64.82
70.42
64.82
70.42
AFUE
63.97
69.51
63.97
69.51
P-4 AFE
53.11
56.89
53.11
56.89
IMPORTANT:
The efficiency rating of this
appliance is a product of thermal efficiency
rating determined under continuous operating
conditions and was determined independently
of any installed system.
GAS LINE CONNECTION
GAS CONVERSION
NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at pressures in excess of ½ psi.
NOTE: The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off
valve during any pressure testing of the gas line at test pressures equal to or less than ½ psi (3.5 kPa).
PAGE 20
ATTENTION: The conversion shall be carried out in
accordance with the requirements of the provincial
authorities having jurisdiction and in accordance with
the requirements of the ANSI Z223.1 installation code.
NOTE: A listed (and Commonwealth of Massachusetts approved) 12” (13 mm) T- handle manual shut-off valve
and flexible gas connector (included) are connected to the 1/2” (13 mm) control valve inlet.
If substituting for these components, please consult local codes for compliance.