VENTING
(Vertical with Decreaser)
For each additional 90
˚
elbow used after the first elbow, 3 ft. (91
4 mm) must be subtracted from the maximum venting allowed. For
each 45° elbow used, 1-1/2 ft. (457 mm) must be subtracted from the maximum venting allowed.
NOTE: (2) 45° degree elbows may be used in place of (1) 90° elbow.
MAXIMUM VERTICAL &HORIZONTAL
COMBINATION VENTING WITH
WITH 8” x 6-5/8” DECREASER
VERTICAL & HORIZONTAL COMBINATION TERMINATIONS
CAUTION: This gas
appliance must not be
connected to or joined with
any other chimney flue
serving another appliance.
MAXIMUM VERTICAL & HORIZONTAL
COMBINATION VENTING
5” x 8”
NOTE: Horizontal sections
require 1/4” (6 mm) rise for
every 12” (305 mm) of travel.
PAGE 31
Depending on your particular venting needs,
a Decreaser may be necessary to terminate
the venting system.
20 FT
(6.10 m)
20 FT
(6.10 m)
IMPORTANT: A WALL THIMBLE PASS-THRU
MUST BE USED ON ALL HORIZONTAL VENT RUNS.
IF USING A 8” x 6-5/8” DECREASER FOLLOW VENT
PIPE MANUFACTURER‟S INSTALLATION
INSTRUCTIONS FOR THEIR WALL THIMBLE.
20 FT
(6.10 m)
20 FT
(6.10 m)
90° ELBOW
90° ELBOW
TERMINATION CAP
TERMINATION CAP
8” x 6-5/8” DECREASER
NOTE: Pages 28-29 have information
on restrictor installation in
conjunction with venting installation.
Page 57 has information on restrictor
recommendations depending on burner flame
appearance and instructions on installation after
venting is completed.