Top of unit face to framing -
10” (254 mm)
From unit left & right sides & back -
1/4” (6 mm)
To flooring -
0” (0 mm)
Unit top to ceiling -
31” (787 mm)
Unit side to adjacent sidewall - 1-
1/2” (38 mm)
Unit front to combustibles -
36” (914 mm)
Top of unit to 3/4” (19 mm) trim
-
10” (254 mm)
Mantel must be a minimum of 16” (406 mm) above top of unit. The maximum mantel depth at this height is
4” (102 mm) deep. See additional mantel clearance configurations on page 16of this installation manual.
SPECIFICATIONS
RIGHT SIDE
LEFT SIDE
GAS LINE HOLE
ELECTRICAL
ACCESS
PAGE 9
8-3/8”
213 mm
5-1/2”
140 mm
9-1/2”
241 mm
CLEARANCES
2-3/4”
70 mm
STAND-OFF
WARNING:
NON-COMBUSTIBLE ZONE:
STAND-OFFS PROVIDE THE
10” (254 mm) MINIMUM
CLEARANCE TO HEADER. USE
ONLY NON-COMBUSTIBLE
MATERIAL IN THIS AREA FOR
THE ENTIRE WIDTH OF FIRE-
PLACE. DO NOT USE WOOD,
SHEETROCK ETC. IN THIS
ZONE.
NOTE: OTHER CLEARANCES
APPLY. THESE CLEARANCES
MUST BE MAINTAINED.
REFER TO PAGE 16 FOR
MORE INFORMATION.
GAS LINE HOLE
FIREPLACE FRONT
FIREPLACE FRONT
THERMOSTAT WIRE
STAND-OFF