DSL-RF-36 LIGHTING AND SHUTDOWN (cont.)
1. Turn off all electrical power to the appliance. (Fan).
2. Open lower grill to access the gas valve & controls.
LIGHTING
A. Push control knob in slightly and turn clockwise to
the
OFF
position. Wait five (5) minutes to clear
out any gas. If you then smell gas,
STOP!
Follow
the safety information on the previous page and on
the front cover of this installation manual. If you
don‟t smell gas, go to the next step.
B. Locate pilot. The pilot is located inside the combustion
chamber.
C. Push the control knob on the gas valve in slightly and turn
counterclockwise to
PILOT.
Push the control knob all the way in and hold. Push the
plunger on the piezo ignitor until the pilot is lit. The pilot
will generally light within two or three pushes on the piezo
ignitor. Hold the knob for about one (1) minute after the pilot
is lit. Release knob and it will pop back out. Pilot should
remain lit. If it goes out, repeat steps A-C.
D. Push the control knob on the gas valve in slightly and
turn counterclockwise to the
ON
position.
NOTE: Gas control knob cannot be turned from
“PILOT” to “OFF” unless knob is pushed in
slightly. Do not force
.
NOTE: When the fireplace is initially lit, condensation will appear on the glass; this is normal in all gas
fireplaces and will disappear after several minutes.
5 MINUTES
1 MINUTE
NOTE: If the manual switch is in the LOCAL position,
the main burner will turn on immediately
.
A.
D.
C.
B.
If knob does not pop up when released, stop and
immediately call your service technician or the gas
supplier.
If the pilot will not stay lit after several
tries, turn the gas control knob to OFF and call
your service technician or the gas supplier.