For each additional 90° elbow used after the first elbow, 3 ft. (914 mm) must be subtracted from the maximum allowed venting.
For each 45° elbow used, 1-1/2 ft. (457 mm) must be subtracted from the maximum venting allowed.
VERTICAL TERMINATIONS (5” X 8”)
MINIMUM: 4 ft. (1.22 m) + cap.
MAXIMUM: 40 ft. (12.19 m) + cap.
HORIZONTAL & VERTICAL COMBINATION TERMINATIONS (5” X 8”)
MAXIMUM: 20 ft. (6.10 m) hori 20 ft. (6.10 m) ve cap. 40 ft (12.19 m) total.
VERTICAL TERMINATIONS (with 8” x 6-5/8” Decreaser)
MINIMUM: 6” (152 mm) + Dec 4 ft. (1.22 m) + cap.
MAXIMUM: 6” (152 mm) + Dec 40 ft. (12.19 m) + cap.
MAXIMUM: 6” (152 mm) ve Dec 20 ft. (6.10 m) hori 20 ft. (6.10 m) ve cap.
HORIZONTAL & VERTICAL COMBINATION TERMINATIONS (with 8” x 6-5/8” Decreaser)
ELBOWS
NOTE: Horizontal Vent Heat Shield is
not used on vertical venting configurations.
A restrictor (included in fireplace components packet) is recommended on all vertical terminations over 6‟ (1.82 m) in length
.
Each installation is unique and affected by various factors including venting configuration, altitude and climate. Therefore, after
fireplace installation is complete a restrictor may be required or may need to be removed or modified.
Please refer to page 29 for installation instructions if installing the restrictor in conjunction with the venting.
Page 57 has information on restrictor recommendations depending on burner flame appearance and instructions on installation
after venting is completed.
RESTRICTOR
VERTICAL VENT SYSTEM CLEARANCES
TOP
BOTTOM
SIDES
DURA-VENT
1 inch (25 mm)
1 inch (25 mm)
1 inch (25 mm)
SELKIRK METALBESTOS
1 inch (25 mm)
1 inch (25 mm)
1 inch (25 mm)
KOZY HEAT #800 SERIES
DO NOT USE FOR VERTICAL TERMINATIONS
VENTING
NOTE: (2) 45° degree elbows may be
used in place of (1) 90° elbow.
PAGE 28