(A) Important inspection part
• Boom
• Arm
METHOD FOR CHECKING AND RELEASING NITROGEN GAS CHARGE PRES-
SURE IN ACCUMULATOR (FOR BREAKER)
(if equipped)
A special tool is needed for checking and charging of nitrogen gas. Ask your Komatsu distributor to perform this
work.
METHOD FOR REPLACING HYDRAULIC TANK BREATHER ELEMENT
k
k
WARNING
• Immediately after the engine is stopped, its parts and oil are still very hot and may cause burn in-
jury. Wait for the temperature to go down, and then start the work.
• When removing the oil filler cap, the oil may spurt out. Turn it slowly to release the internal pres-
sure, then remove it carefully.
MAINTENANCE PROCEDURE
MAINTENANCE
4-60