METHOD FOR STARTING ENGINE
1.
Check both of normal machine and failed machine that the lock lever is set to LOCK position.
Check also that all the control levers are in NEUTRAL position.
2.
Make sure the clips are firmly connected to the battery terminals.
3.
Start the engine of the normal machine and run it at high idle (max. speed).
4.
Turn the starting switch of the failed machine to START position and start the engine.
If the engine does not start, try again after at least 2 minutes.
PROCEDURE FOR REMOVING JUMPER CABLE
After the engine has started, disconnect the jumper cables in the reverse of the order in which they were con-
nected.
1.
Remove the clip of jumper cable (B) from the revolving
frame (E) of the failed machine.
2.
Remove the clip of jumper cable (B) from the negative (-)
terminal of battery (D) on the normal machine.
3.
Remove the clip of jumper cable (A) from the positive (+)
terminal of battery (D) on the normal machine.
4.
Remove the clip of jumper cable (A) from the positive (+)
terminal of battery (C) on the failed machine.
OTHER TROUBLE
PHENOMENA AND ACTIONS FOR ELECTRICAL SYSTEM
• For the remedies indicated with (*) in the remedy column, always contact your Komatsu distributor.
• In cases of problems or causes which are not listed below, ask your Komatsu distributor for repairs.
Problem
Main causes
Remedy
Lamp does not glow brightly even
when the engine runs at high
speeds.
Defective wiring, deterioration of bat-
tery
Check and repair loose terminal or
wire breakage, replace battery. (*)
Loosening and damage of alternator
belt
Check alternator belt tension and re-
place. (*)
Lamp flickers while engine is run-
ning.
Defective wiring, deterioration of bat-
tery
Check and repair loose terminal or
wire breakage, replace battery. (*)
Loosening and damage of alternator
belt
Check alternator belt tension and re-
place. (*)
Charge level caution lamp does not
go out even when engine is running.
Defective alternator
Replace. (*)
Defective wiring
Check, repair. (*)
Unusual noise is generated from al-
ternator.
Defective alternator
Replace. (*)
Starting motor does not rotate even
when starting switch is turned to
START position.
Defective wiring
Check, repair. (*)
Defective starting motor
Replace. (*)
Insufficient battery charge
Charge battery.
Battery disconnect switch at OFF po-
sition
Turn ON.
Engine shutdown secondary switch
at “STOP ENGINE” position
Set it to “NORMAL” position.
Apply the cover.
OPERATION
TROUBLES AND ACTIONS
3-245
Summary of Contents for PC700LC-11
Page 2: ......
Page 23: ...LOCATION OF SAFETY LABELS 5 SAFETY SAFETY LABELS 2 3...
Page 66: ......
Page 316: ......
Page 396: ......
Page 397: ...SPECIFICATIONS 5 1...
Page 401: ...For 7 6m Boom SPECIFICATIONS SPECIFICATIONS 5 5...
Page 402: ...SPECIFICATIONS SPECIFICATIONS 5 6...
Page 426: ......
Page 427: ...REPLACEMENT PARTS 7 1...
Page 434: ......