Index
Sub-
index
Data
Type
Float
Scale
Access PDO
map.
Description
ASCII object
3416h
0
U32
RO
no
Gets regen resistor's cal-
culated power
REGEN.POWER
3417h
0
U32
RO
no
Returns a filtered version of
3416h
REGEN.POWER-
FILTERED
3420h
0
U16
1000:1
RW
no
Sets the foldback fault level.
IL.FOLDFTHRESH
3421h
0
U32
1000:1
RW
no
Sets the user value for the fold-
back fault level.
IL.FOLDFTHRESHU
3422h
0
U32
1000:1
no
Sets friction compensation
value.
IL.FRICTION
3423h
0
INT32
1000:1
no
A constant current command
added to compensate for grav-
ity.
IL.OFFSET
3424h
0
U16
no
Enables/disables the integ-
rator part of the PI loop.
IL.INTEN (Password Pro-
tected)
3425h
0
U32
1000:1
RO
no
Reads the overall foldback cur-
rent limit
IL.IFOLD
3426h
0
U32
1000:1
RW
no
Sets current loop acceleration
feedforward gain value
IL.KACCFF
3427h
RECORD
Motor protection parameters
—
3427h
0
U8
RO
no
highest sub-index
—
3427h
1
U8
RW
no
IL.MIMODE
3427h
2
U8
RW
no
IL.MI2TWTHRESH
3427h
3
U32
RW
yes
IL.MI2T
3430h
0
U8
RW
no
Sets the direction for absolute
motion tasks.
PL.MODPDIR
3431h
0
U16
RW
no
Sets the motion task in the
drive
MT.SET
3440h
ARRAY
Controlled stop parameters
—
3440h
0
U8
RO
no
highest sub-index
—
3440h
1
U32
1:1
RW
no
Sets the deceleration value for
a controlled stop.
CS.DEC
3440h
2
U32
1:1
RW
no
Sets the velocity threshold for
a controlled stop.
CS.VTHRESH
3440h
3
U32
RW
no
Sets the time value for the
drive velocity to be within
CS.VTHRESH.
CS.TO
3441h
0
U8
RO
no
Controlled stop state
CS.STATE
3443h
0
U16
RO
no
Returns the possible reason
for a drive disable
DRV.DIS
3444h
0
U16
1000:1
RO
no
Maximum current for dynamic
braking
DRV.DBILIMIT
3445h
0
U32
RO
no
Emergency timeout for brak-
ing
DRV.DISTO
3450h
0
U8
WO
no
Release or enable brake
MOTOR.BRAKERLS
3451h
0
U8
RW
no
Determines which drive para-
meters are calculated auto-
matically.
MOTOR.AUTOSET
AKD EtherCAT | 5 Appendix
Kollmorgen | kdn.kollmorgen.com | October 2017
71