AKD EtherCAT | 5 Appendix
5.3.4 Object 1003h: Predefined Error Field (DS301)
The object 1003h provides an error history with a maximum size of 10 entries.
Subindex 0 contains the number of errors which have occured since the last reset of the error
history, either by startup of the drive or resetting the error history by writing 0 to subindex 0.
A new Emergency-message is written into subindex 1 shifting the old entries one subindex
higher. The old content of subindex 8 is lost.
The UNSIGNED32-information written to the subindizes is defined in the field Error Code in
the description of the Emergency Messages (
p. 59).
Index
1003h
Name
pre-defined Error Field
Object code
ARRAY
Data type
UNSIGNED32
Category
optional
Subindex
0
Description
highest sub-index supported
Data type
UNSIGNED8
Category
mandatory
Access
R/W
PDO mapping
not possible
Value range
0 to 10
Default value
0
Subindex
1 to 10
Description
Standard error field (
Category
optional
Access
R/O
PDO mapping
not possible
Value range
UNSIGNED32
Default value
no
94
Kollmorgen | kdn.kollmorgen.com | October 2017