26
Configuration
StorCase Technology, Inc.
DS560/DS570 User's Guide - Rev. A04
Single Host Configuration for Logical Units
A RAID array may be divided into multiple logical units. A logical unit is that portion of a disk
array seen by the host system as a single logical device. Each logical unit is identified to the
host by its Logical Unit Number (LUN). The RAID Controller can support up to eight (8) logical
units.
1.
Make sure Single Host Configuration is completed first.
2.
Press
Enter
to open the
6 RAID Funcs
menu.
3.
Press
ê
until the
62 Init R5/R3
menu is displayed, then press
Enter
.
4.
Press
ê
until the STOP option is displayed, then press
Enter
.
5.
Press
Esc
to return to the Main Menu.
6.
Press
Enter
to open the
1 RAID Params
menu.
7.
Press
ê
until the
14 Slice
menu is displayed, then press
Enter
.
NOTE:
Slice will allow you to divide the partition size.
8.
Press
ê
until the
141 Slice 0(MB)
menu is displayed, then press
Enter
.
9.
Key in the desired capacity in Slice 0, then press
Enter
.
10.
Press
ê
to select the
142 Slice 1(MB)
to
148 Slice 7(MB)
, repeat Steps 8-9.
11.
Press
Esc
to return to the Main Menu.
12.
Press
ê
until the
2 SCSI Params
menu is displayed, then press
Enter
.
13.
Press
ê
until the
216 LUN Map
menu is displayed, then press
Enter
.
14.
Press
ê
until the
2161 LUN 0
menu is displayed, then press
Enter
.
15.
Refer to Table 5 to set-up LUN menu.
LUN 0
LUN 1
LUN 4
LUN 3
LUN 2
LUN 5
LUN 7
LUN 6
Slice 0
Slice 1
Slice 2
Slice 3
Slice 4
Slice 5
Slice 7
Slice 6
Table 5: LUN Set-Up
16.
Press
Esc
to return to the Main Menu.
17.
Press
ê
until the "5 NVRAM" menu is displayed, then press
Enter
.
18.
Press
ê
until the "51 Update NVRAM" menu is displayed, then press
Enter
.
19.
Press
ê
until the YES option is displayed, then press
Enter
.
20.
Press
ê
until the "53 Restart" menu is displayed, then press
Enter
.