DS560/DS570 User's Guide - Rev. A04
StorCase Technology, Inc.
Configuration
25
14.
Use the
ê
button to enable /disable the SCSI termination for the RAID Controller, then
press
Enter
.
NOTE:
If the RAID Controller is at the end of the SCSI bus, termination should be
enabled. If the RAID Controller is in the middle of a SCSI bus, termination
should be disabled.
15.
Press
ê
until the
23 Tag Queuing
menu is displayed, then press
Enter
.
16.
Use the
ê
button to enable /disable the Tag Queuing for the RAID Controller, then
press
Enter
.
NOTE:
The default setting for Tag Queuing is enabled. Tag Queuing allows the
RAID Controller to process multiple requests, which improve performance.
17.
Press
ê
until the
224 Ultra
and
225 Wide
menus are displayed, then press
Enter
.
18.
Refer to Table 4 to set-up the SCSI interface of the Host.
SCSI
Interface
Wide
Fast
Ultra
Ultra2
SCSI-2
Wide SCSI
Disable
Ultra3
Ultra SCSI
Ultra Wide SCSI
Ultra2 SCSI
Ultra160 SCSI
Disable
Enable
Enable
Enable
Enable
[ENT]
[ENT]
[ENT]
[ENT]
[ENT]
[ENT]
Table 4: SCSI Set-Up
19.
Press
Esc
to return to the Main Menu.
20.
Press
ê
until the
5 NVRAM
menu is displayed, then press
Enter
.
21.
Press
ê
until the
51 Update NVRAM
menu is displayed, then press
Enter
.
22.
Press
ê
until the YES option is displayed, then press
Enter
.
23.
Press
ê
until the
53 Restart
menu is displayed, then press
Enter
.
24.
Press
ê
until the YES option is displayed, then press
Enter
.
NOTE:
This will automatically restart the RAID Controller.