3.
Control unit setting
3.1 -
Dip-switch adjustment
1
23
45
6
78
1
23
45
6
78
1
8
ON
DIP
DIP-SWITCH status
Description of operation
DIP 1-2
MOTOR
1 ON 2 ON
Connected gearmotors: swing series “Jet 24V”, “JetXL 24V”, “Linear 24V”, “Intro 24-400” or “Couper24”
1 ON 2 OFF
Connected gearmotors: “Modus” series swing gate
1 OFF 2 ON
Connected gearmotor: sliding series “Dynamos 24V”
1OFF 2 OFF
Connected gearmotor: swinging series “Minimodus”
DIP 3
STEP
3 ON 4 OFF
Step-by-step command mode: Open / Stop / Close / Stop
3 ON 4 ON
Step-by-step with automatic closing (time set with the “Pause” knob)
DIP 4
AUTO
3 OFF 4 ON
Opening only command mode with automatic closing (condominium function)
3 OFF 4 OFF
Open / Close / Open command mode (no Stop)
DIP 5
PHO2
ON
Safety devices connected to “PH 02” set as photocells (stop of the movement both in opening
and closing phases with opening manoeuvre after PH 02 clearance)
OFF
Safety devices connected to “PHO2” set as edges (immediate inversion; active just in opening phase)
DIP 6
HAZ
ON
Warning light flashing during cycle
OFF
Warning light on during cycle
DIP 7
FAST
ON
Gate recloses immediately after vehicle passes “PH 01” safety devices (photocells)
OFF
Standard operation - safety devices do not command a reclosing manoeuvre
DIP 8
FUNC
SWINGING
(see DIP 1-2)
ON
Ram function enabled
OFF
Ram function disabled
SLIDING
(see DIP 1-2)
ON
Reverse opening direction (automation’s movement must be programmed afterwards)
OFF
Reverse opening direction (automation’s movement must be programmed afterwards)
2
DIP SWITCHES
(Paragraph 3.1)
DIP1-2 “MOTOR”:
Set these dip switches to suit the type of motors in use for this
installation.
DIP3 “STEP” :
ON
- step by step, a command will open, stop, or close the gate
OFF
- setup for fully automatic, condominium ( apartment block )
DIP4 “AUTO”:
If the dip-switch is put to
ON
, the automatic re-closing function is
activated. The control unit automatically closes the leaves after the
time set through the “
PAUSE
” trimmer (see Paragraph 3.2). If the
“
AUTO
” dip-switch is put to
OFF
, the automatic re-closing function
is deactivated. To close the leaves, therefore, a command must be
given (either wired or via transmitter).
DIP5 “PHO2”:
ON
-
Gate will stop on opening and closing ( for photocells )
OFF
- Gate will stop and retract in the opposite direction slightly (for
safety edge)
A variation of DIP 1-2 “MOTOR” and DIP 8 “FUNC” (if the
control unit is set to sliding gate) will not become effective
until a new gate
travel