StarG8 24 Accessories wiring connection
TIMER FUNCTION: if START contact is kept closed (for instance through a timer-controlled or bistable relay), control unit
opens the gate and leaves the gate opened. The automation does not accept closing commands (neither automatic nor wired)
until START contact is reopened.
In this mode, dip switch 3 STEP is set to OFF and dip 4 AUTO to ON
If START contact is kept closed during the control unit starting after a blackout, the gate will immediately execute the st
a
rt
command.
11)
)
)))
2
22 Multiple devices connected to a
single input must be connected in
series.
switches are used.
parallel.
Default: electric lock 12Vdc max. 15W
(for courtesy light enable, see par. 13)
Closing: normally closed contact PHO1
Opening: normally closed contact PHO2
COMMON of terminals 5-6-8-9
Power supply 24 VDC
Positive gate PILOT LIGHT (24 VDC, max 3W)
Opening limit switch motor 1
Closing limit switch motor 1
Common of terminals 10-11-13-14
Opening limit switch motor 2
Closing limit switch motor 2
START normally open contact
COMMON of terminals 15-17-18
STOP normally closed contact
PEDESTRIAN N.O. contact
Antenna ground
Antenna signal
[2]
[1]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
[14]
[15]
[16]
[17]
[18]
[19]
[20]
AUX contact /
electric lock
(Paragraph 9.4)
Safety device
contacts
(Paragraph 9.5)
24V power supply/
gate pilot lamp
(Paragraphs 9.6/9.7)
Limit switch
(Paragraph 9.8)
Wired commands
(Paragraph 9.9)
Antenna
(Paragraph 9.10)
Warning light
(Paragraph 9.3)
24Vdc max.15W warning light
[4]
[3]
leave the limit switch
terminals free if no limit
any devices connected to
“START” (terminal 15) or
“PED”(terminal 18) inputs must
be dry contacts (voltage free).
Multiple devices connected to a
single input must be connected in
Sliding gate motors are provided
with limit switches
(terminal 6) or “STOP” (terminal 17)
For safety devices connected to
“PHO1” (terminal 5), “PHO2”
Inputs must be dry contacts
(voltage-free), and the relevant
factory bridge must be removed.
when using an external antenna,
remove the connected wire