2-6
Installation and Preparation for Use
TOS6200A/6210
3.
Connect the current output line on the crimp terminal side of the test
lead (red) to the HIGH side of the OUTPUT terminals; connect the volt-
age measurement line on the banana plug side to the HIGH side of the
SAMPLING terminals. Check that the connections are secure.
• Improper terminal connections can result in inaccurate measurements and
burns or injury resulting from heat generated by contact resistance at the
terminals.
4.
Connect the alligator clip of the test lead (black or white) to the protec-
tive conductor terminal of the DUT.
5.
Connect the alligator clip of the test lead (red) to a test point of the DUT.
For details, see 2.4.6, "Connecting to the DUT”
• Make sure that the alligator clip connections are secure.
Improper connections may result in clip disconnection, causing sparking
and potentially damaging the DUT.
WARNING
Connecting example of TOS6200A