9-8 Specifications
PLZ-4W
9.2
General Specifications
Model
PLZ164W
PLZ334W
PLZ1004W
PLZ164WA
PLZ664WA
Input voltage range
100 VAC – 240 VAC
(90 VAC – 250 VAC)
Single phase, continuous
100 VAC – 120 VAC /200 VAC – 240 VAC
(90 VAC – 132 VAC/180 VAC – 250 VAC)
Single phase
Input frequency range
47 Hz – 63 Hz
Power consumption
80 VAmax
90 VAmax
160 VAmax
450 VAmax
1500 VAmax
*1
*1. 900 VA when input voltage is 100 VAC.
Inrush current
45 A
80 A
Operating temperature range
0
°
C to 40
°
C (32
°
F to 104
°
F)
Operating humidity range
20 % - 85 % RH (without condensation)
Storage temperature range
-25
°
C to 70
°
C (-13
°
F to 158
°
F)
Storage humidity range
90 % RH or less (without condensation)
Isolation voltage
±
500 V
Insulation
resistance
Primary - input
terminal
500 VDC, 30 M
Ω
or more (ambient humidity of 70 % RH or less)
Primary - chassis
500 VDC, 30 M
Ω
or more (ambient humidity of 70 % RH or less)
Withstand
voltage
Primary - input
terminal
No abnormalities at 1500 VAC for 1 minute.
Primary - chassis
No abnormalities at 1500 VAC for 1 minute.
Dimensions (mm)
See outline drawing
Weight
Approx. 7 kg
(15.43 lb)
Approx. 8 kg
(17.64 lb)
Approx. 15 kg
(33.07 lb)
Approx. 7.5 kg
(16.53 lb)
Approx. 16 kg
(35.27 lb)
Battery backup
Backs up setup information
Accessories Power cord
1 pc. (with plug, Length: approx. 2.4 m)
Load input
terminal cover
1 piece
2 lock plates provided
Set of screws for
the load input
terminal
2 sets (bolts, nuts, and spring washers)
Setup Guide
1 piece (Japanese, English)
Quick Reference
Japanese: 1 piece, English: 1 piece
CD-ROM
*2
*2. Contains Application & Samples, User’s manual, the Communication Interface Manual and KI-VISA.
1 piece
Electromagnetic compatibility
(EMC)
*3
*3. Only on models that have CE marking on the panel. Not applicable to custom order models.
Complies with the requirements of the following directive and standards.
EMC Directive 2004/108/EC
EN 61326-1
EN 61000-3-2
EN 61000-3-3
Complies with the
requirements of the
following directive
and standards.
EMC Directive
2004/108/EC
EN 61326-1
Under following condition.
The maximum length of all connecting cables and wires to the PLZ-4W series are less than 3 m.
Safety
*4. This instrument is a Class I equipment. Be sure to ground the protective conductor terminal of the instrument.
The safety of the instrument is not guaranteed unless the instrument is grounded properly.
Complies with the requirements of the following directive and standard.
Low Voltage Directive 2006/95/EC
EN 61010-1
Class I
Pollution degree 2
Summary of Contents for PLZ-4W Series
Page 10: ...VIII Contents PLZ 4W ...
Page 20: ...1 10 General Information PLZ 4W ...
Page 38: ...2 18 Installation and Preparation PLZ 4W ...
Page 90: ...5 30 Basic Operation PLZ 4W ...
Page 192: ...9 10 Specifications PLZ 4W ...
Page 214: ...A 22 Appendix PLZ 4W ...