Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™
Screens - Spine Screen 10-Wire Power
Assembly Instructions
Figure 5
Spine Screen
10-wire
duplex
receptacle
10-wire
jumper
10-wire
rigid wireway
10-wire
duplex
receptacle
10-wire
duplex
receptacle
10-wire
duplex
receptacle
10-wire
jumper
Spine Screen
Detail I
10-wire
rigid wireway
mounting
plate
10-wire duplex
receptacle
Detail J
inner socket
of 10-wire
rigid wireway
10-wire duplex
receptacle
Detail K
wedges on
receptacle
catch
clip
10-wire duplex
receptacle
Electrical Installation - Overview
Important:
Assembly of all frame
components must be completed,
with screen frames properly leveled
and mechanically secured to each
Duplex Receptacle Installation
Note:
Duplex receptacles for the
10-wire system are specified/
ordered separately. Six receptacles
are available for accessing one of
each of the six circuits of the 10-wire
system. They are designed with a
numeral on each (i.e. 1, 2, 3, 4, 5, &
6). Circuits 4, 5 and 6 have triangles
to identify them as isolated circuits.
To install the receptacles, follow the
steps below.
WARNING:
Assembly of all
mechanical components must
be completed before making any
electrical connections. All electrically
connected furnishings must also be
mechanically connected.
1. Per the space-planning layout,
determine the correct location for
each numbered receptacle in the
system (Figure 5).
2. Position the duplex receptacle on
either end of the 10-wire rigid
wireway as shown, matching the
arrow at the “N” symbol to the same
orientation on both the receptacle
and the wireway (Figure 5).
3. Align the receptacle so the end is
in-line with the inner socket on
the rigid wireway and push the
receptacle back against the mounting
plate (Detail I).
4. Slide the receptacle to the side so
the end terminals slide into the rigid
wireway’s inner socket (Detail J).
5. Receptacle is properly seated when
the catch clip on the wireway is
snapped in between the wedges on
the receptacle (Detail K).
other prior to installation of electrical
components.
Connection to the building power
supply may be made ONLY after all
screen wiring has been completed.
Building connections must be made
by a licensed electrician, following
local codes at the building site.
Note:
Each circuit must be
individually protected with a
120-volt, 20-amp circuit breaker
device which will provide disconnect
and overload protection.
Prior to beginning electrical
component installation, read and
understand the following electrical
installation section and be familiar
with the electrical components and
all power infeed locations required.
Note:
Each powered Spine Screen
has two 10-wire rigid wireways that
are pre-mounted in the base raceway
at the factory.
Note:
Spine Screen electrical is
“in-line” only and does not turn
corners. Spine Screens cannot pass