Maintenance
Every 250h
4. Cover the inlet on the back of the body
with cloth or tape to prevent dust from
entering.
5. Clean the inside of the shell.
6. Clean the filter element with dry pressure
air (294 to 490kPa). First blow air from the
inside of the filter element along the
gathers. Then blow from the outside, and
finally from the inside.
7. Use a light bulb to illuminate the inside of
the filter element and perform inspection.
If there are small holes or stains, replace it.
8. Install the filter element and tighten it.
9. Install the shell and tighten it.
Checking of accelerator control
system
l
The accelerator joystick and the speed
regulator on the engine side are connected
by wiring. Check the wires at their fixing
positions for presence of stretching and
looseness.
l
If the wires at their fixing positions are
stretched or loose, there probably has a
malfunction.
l
The replacement and adjustment of wires
require experiences. Please ask your sales or
service dealer for operations.
5-30
Summary of Contents for XN10-8
Page 9: ...Safety 1 1...
Page 44: ...Safety Safety Signs 1 36...
Page 49: ...Controls 2 1...
Page 55: ...2 7 Records...
Page 64: ...Operations 3 1...
Page 87: ...Operations Parking of This Machine Locking Ensure to lock the following parts 3 24...
Page 93: ...Transportation 4 1...
Page 97: ...Transportation Lifting of Machine 4 5 unit mm...
Page 99: ...Maintenance 5 1...
Page 112: ...5 14 Records...
Page 120: ...5 22 Records...
Page 130: ...5 32 Records...
Page 132: ...5 34 Records...
Page 144: ...Troubleshooting 6 1...
Page 155: ...Parameters 7 1...
Page 159: ...Parameters Lifting power 7 5...
Page 160: ...7 6 Records...
Page 161: ...Optional products 8 1...
Page 170: ...8 10 Records...
Page 172: ...Optional products Canopy 8 12...
Page 173: ...Parts number position Upper frame number 20060001 8 13...