Series 2280 Precision DC Power Supply Reference Manual
Section 5: Application examples
077085503 / March 2019
5-5
Configure a 10-step linear list sweep
To configure a list on the front panel:
1. Press the
MENU
key.
2. Under Source, highlight the
List
icon using either the navigation control or the soft keys. Press
ENTER
.
3. Select point 1 and press
ENTER
to select the box.
4. Highlight
Insert
and press
ENTER
to increment the points display until it reads 10.
5. Select the Voltage box in the point 1 row. Press
ENTER
.
6. Make the value 1 V and press
ENTER
.
7. Select the Current box in the point 1 row. Press
ENTER
.
8. Make the value 2 A and press
ENTER
.
9. Select the Dwell box in the point 1 row. Press
ENTER
.
10. Make the value 3 s and press
ENTER
.
11. Repeat steps 5 to 8 for points 2 to 10 and increase the voltage by 1 V at each higher step.
12. Select the
Save
button to store the list in memory location 1.
13. Enter a name for the list on the displayed keypad and press
ENTER
.
14. Press the
EXIT
key.
Figure 86: Edit a 10-step list