Operators Manual
Section 5-13
View of Head Timing Sprocket & Sensors
4.
The next procedure is to make the position sensors come
“ON” in the MIDDLE of the proximity sensors. To do this,
you must enter the Managers Menus and advance to the
ADJUST HEAD SENSOR screen.
NOTE
: The distance between the metal target on the oil
head and the proximity sensor should be a gap of
0.038
".
5.
Once in the ADJUST HEAD SENSOR menu press the NEXT key
and you will see:
LFT PROX #12 OFF
POS SENSOR #1 OFF
6.
Move the oil head all the way to the 7-pin side wall
(outside of the prox). Slowly move the head
toward the
middle
of the proximity sensor. When the screen reads
LEFT PROX ON, slowly continue to move the oil head from
left to right.
7.
When the screen changes and reads POS SENSOR #1 ON, stop
moving the head. The timing mark on the top center of
the head should be in the center of the left prox (the
center of the head and prox are both marked).
Oil Head
Metal Target
Timing
Mark
Board
Sprocket
Right to
Left Oil
Head
Position
Sensor (#2)
Proximity
Sensor
Left to Right
Oil Head
Position Sensor
(#1)