Operators Manual
Section 2-10
SPRAY JET ASSEMBLIES:
Mounted to the front outer wall are
the 4 spray jet assemblies. These assemblies can be
angled up or down, and left or right, to adjust spray
coverage to the entire lane. Mounted with the spray tip
is a combination check valve/filter.
DUSTER UP SWITCH:
Located on each side wall above the
duster cushion roller pivot arms is a microswitch. These
switches, when actuated, tell the PC that the cushion
roller is in the UP position.
FAILSAFE SWITCH:
These switches are found on each side
wall, below the Duster Up switches. When the cushion
roller drops off the end of the lane, the cushion roller
pivot arms actuate the failsafe switches. Once actuated,
the machine will travel two inches before it reverses.
The failsafe will reverse the machine only when the End
Cleaning Distance counter is set too high. The failsafe
switches are a backup system only!