Operators Manual
Section 8-3
2.
Press
MENU
three times to access the:
* PUMP OUTPUT
VOLUME TEST
No Password is needed to access this menu.
3.
a.) If the machine is already warmed up, press
NEXT
twice to access the:
TEST: VOLUME PER
BOARD HIT: <-->
If the pump has been running skip to Step 8.
b.) If the machine is not warmed up press
NEXT
three times to access this display:
TEST:VOL PER REV
FOR 0490 REVS
The pump will begin running as soon as this screen
appears. The pump should run between 460 and 510
at 60 Hertz and 385 to 430 for 50 Hertz.
4.
Place a small container under the calibration
outlet on the left rear panel.
5.
When the
LEFT ARROW
is pressed the number on the
screen will change to zero and the pump output
will begin running out of the calibration outlet.