Operators Manual
Section 8-10
7.
Then press the
RIGHT ARROW
to start the head
travel. The output of the pump is routed to the
calibration outlet instead of the transfer roller.
8.
When the head stops moving, the FWD in the bottom
left corner of the screen will change to
REV
.
This tells you the machine is now ready to apply
the reverse oil loads.
TEST: PROGRAM#01
REV OIL VOL.<-->
9.
Press the
LEFT ARROW
to start the pump and wait
about 5 seconds.
10.Then press the
RIGHT ARROW
to start the head
travel and dispense the 3 reverse loads.
11.When the head stops moving, remove the graduated
cylinder and read the amount of oil.
12.The bottom of the oil line should be between
18.5
and
19
milliliters.
Running this test 3 or 4 times should be
enough to convince anyone of the
machine's
accuracy and repeatability. Any time you run a
different program you should calculate the total
boards and volume.
Blank worksheets are provided at the back of
the lane graph section to assist with this task.
Having the total output for the program will
insure that the program values are entered
correctly. It will also help you to better
understand each change you do make.