Operators Manual
Section 4-3
C. Turning the Unit On
Carefully set the machine in the operating position on
the approach. It should be completely on the approach, with
the cleaning end being approximately 6 inches behind the
foul line.
Connect the twistlock connector on the power cord to
the machine
.
Connect the power cord into a suitable outlet. MAKE
SURE THAT THE OUTLET IS SUPPLYING THE CORRECT VOLTAGE AND
AMP RATING (see Page 1). Connecting the power cord into an
outlet located toward the center lanes of the establishment
will allow more lanes to be cleaned and/or conditioned
without changing outlets.
The power cord supplied with the machine will be long
enough to clean in excess of 24 lanes without the need to
change outlets. (To accomplish cleaning the maximum number
of lanes, the cord should be plugged into an outlet at
approximately Lane 12. This will allow enough slack in the
cord to place it out of the machine’s path as it
cleans/conditions lanes 1-24.)
When power is applied to the machine, the menu screen
on the keypad will illuminate. The machine is now ready to
run.
If the machine does not appear to have any power after
it has been plugged in, check the E-STOP switch to make sure
it hasn’t been accidentally pressed. Rotate the red button
to reset this switch. Power will resume immediately.